EFBI Gamma Series Reverse Osmosis Systems

CODE: GM-001

EFBI Gamma Series Reverse Osmosis Systems

CODE: GM-001

EFBI GAMA SERIES REVERSE OZMOZING SYSTEMS 150 m3/day to 1650 m3/day It is a water treatment system applied to waters (sea water, waters with high conductivity, well waters, etc.) where classical treatment systems are insufficient..

About the Product

EFBI GAMA SERIES REVERSE OSMOSIS SYSTEMS
150 m³/day to 1,650 m³/day

 

Reverse osmosis is a membrane filtration process used to treat water where conventional purification systems fall short (such as seawater, highly conductive water, well water, etc.), which removes all unwanted minerals from the water to produce pure water. Osmosis is a natural phenomenon and, in short, is the movement of water from a less concentrated solution to a more concentrated one. This process continues until osmotic equilibrium is achieved. Reverse osmosis, however, is the reversal of this osmotic flow. EFBİ Reverse Osmosis Systems successfully ensure the production of pure water as a result of this process. EFBİ Reverse Osmosis Systems can be manufactured in various designs and configurations according to customer requirements.

STANDARD FEATURES

  • FRP membrane housings
  • TFC spiral-wound membranes, 8″ diameter
  • AISI304 or AISI316 grade stainless steel vertical centrifugal high-pressure pump
  • ST-37 epoxy-coated carbon steel or AISI304 stainless steel frame
  • 5-micron precision cartridge filter
  • Low-pressure line: U-PVC PN16
  • High-pressure line: AISI 304 stainless steel
  • Inlet butterfly valve with electric actuator
  • Pressure-regulating globe valves on the pump outlet and wastewater line
  • Low and high-pressure switches
  • Product water and wastewater flow meters
  • Glycerin-filled pressure gauges
  • Product water conductivity meter (0-2000 µS/cm)
  • Product water pH meter (optional)
  • Autoflush, automatic rinsing, and chemical cleaning system
  • On-Off switch
  • PLC and operator panel
  • 380 V/50 Hz/3-phase
  • IP56 control panel

 

Recommended Inlet Water Limits

Inlet water TDS: 0 – 2,000 ppm
Operating pressure: 10 to 15 bar
Inlet water pressure: 2 to 5 bar If
hardness exceeds 3 French units, ASC dosing is required
pH range: 6 – 8
Silica (SiO₂) tolerance: 25 ppm max. @ 60% efficiency
Max. Inlet water temperature = 30°C Max.
Iron (Fe) tolerance: 0.05 ppm, 0.2 ppm
if ASC is dosed. Hydrogen sulfide must not be present.
Turbidity must not be present (NTU)